aboutsummaryrefslogtreecommitdiffstats
path: root/DOCS/vt102-ug/chapter7.html
blob: cee791e6a5a41dcde0c2a515bc24b6ac39cb45ea (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01//EN" "http://www.w3.org/TR/html4/strict.dtd">
<HTML>
<HEAD>
<TITLE>VT100.net: Digital VT102 User Guide</TITLE>
<LINK HREF="vt102-ug.css" TYPE="text/css" REL="stylesheet">
</HEAD>
<BODY>
<DIV CLASS="navbar"><A HREF="http://vt100.net/"><IMG CLASS="button" SRC="vt100.net-logo.png" ALT="VT100.net" HEIGHT="16" WIDTH="102"></A> VT102 User Guide<TABLE WIDTH="100%">
<COL SPAN="3" WIDTH="33%">
<TBODY>
<TR>
<TD ALIGN="LEFT"><A HREF="chapter6.html">Chapter 6</A></TD>
<TD ALIGN="CENTER"><A HREF="contents.html">Contents</A></TD>
<TD ALIGN="RIGHT"><A HREF="chapter8.html">Chapter 8</A></TD>
</TR>
</TBODY>
</TABLE>
<HR></DIV>
<H1 ID="S7"><SPAN CLASS="chapnum">7</SPAN> Installation</H1>
<H2 ID="S7.1">General</H2>
<P>This chapter provides information used to unpack, pack, and install the
VT102. The installation procedure describes how to select the input voltage
switch and fuse. The chapter also provides a step-by-step power-up
and checkout procedure.</P>
<H2 ID="S7.2">Site Considerations</H2>
<P>The terminal consists of a video monitor and a detached keyboard. <A HREF="figure7-1.html">Figure
7-1</A> shows their dimensions. The following list covers the terminal's environmental
and power specifications.</P>
<TABLE>
<TBODY>
<TR VALIGN="TOP">
<TD>Temperature</TD>
<TD>10&deg; to 40&deg; C (50&deg; to 104&deg; F)</TD>
</TR>
<TR VALIGN="TOP">
<TD>Relative humidity</TD>
<TD>10 to 90 percent with a maximum wet bulb temperature
of 28&deg; C (82&deg; F) and a maximum dew point
of 2&deg; C (36&deg; F) noncondensing</TD>
</TR>
<TR VALIGN="TOP">
<TD>Input voltage</TD>
<TD>99 to 128 Vac (115 V setting)<BR>
198 to 256 Vac (230 V setting)<BR>
or<BR>
87 to 107 Vac (100 V setting)<BR>
222 to 268 Vac (250 V setting)</TD>
</TR>
<TR VALIGN="TOP">
<TD>Power&nbsp;consumption</TD>
<TD>70 W</TD>
</TR>
<TR VALIGN="TOP">
<TD>Power receptacle</TD>
<TD>Nonswitched, grounded</TD>
</TR>
</TBODY>
</TABLE>
<P>When installing the terminal, make sure that all power and signal cables
are free from stress, sharp bends, or obstructions. Also, make sure to provide
access to monitor controls on the back of the terminal.</P>
<P>Several ventilation openings prevent the terminal from overheating. Do
not block the air flow around these openings by placing objects on top of
or under the terminal. Also, do not allow liquids, coins, paper clips, or other
objects to enter these ventilation openings. These objects may damage
the terminal.</P>
<P>You can place the terminal on a desk or tabletop. However, operators
usually prefer the keyboard at standard typewriter-table height rather than
desk height. Terminal tables and stands are available from the DIGITAL
Accessories and Supplies Group (A&amp;SG). (See <A HREF="chapter10.html">Chapter 10</A> for more information
on accessories).</P>
<P>Position the video monitor to avoid reflected light. The screen should face
away from light sources. However, if reflected light is a problem, filter
screens are available from A&amp;SG.</P>
<P>For installations with static electricity problems, static mats are available
from A&amp;SG.</P>
<H2 ID="S7.3">Unpacking and Inspection Procedure</H2>
<P>The terminal is packed in a carton with the following items.</P>
<UL>
<LI>Monitor</LI>
<LI>Keyboard</LI>
<LI>AC power cord(s)</LI>
<LI>SET-UP label</LI>
<LI>User guide</LI>
<LI>Programming reference card</LI>
</UL>
<P><A HREF="figure7-2.html">Figure 7-2</A> shows the terminal's packaging. Unpack the terminal from the
shipping carton by using the following procedure.</P>
<OL>
<LI>Cut the carton sealing tape and open the carton flaps.</LI>
<LI>Lift the non-US power cord out of the carton. This power cord is supplied
with some variations of the terminal.
<P CLASS="note">NOTE: All terminals are shipped with a US power cord.</P></LI>
<LI>Lift the terminal out of the carton by using the handles in the packing
material. Place the terminal and packing on its left side (when facing
the front of the terminal).</LI>
<LI>Remove the packing material on the right side.</LI>
<LI>Remove the keyboard and keyboard cover, then the monitor from the
left-side packing material.</LI>
<LI>Remove the plastic bags covering the monitor and keyboard.</LI>
<LI>Inspect the terminal for damage.
<P CLASS="note">NOTE: Notify the carrier and your local DIGITAL Sales Office of any
damage.</P></LI>
<LI>Install the terminal by using the installation procedure in this chapter.</LI>
</OL>
<H2 ID="S7.4">Packing Procedure</H2>
<P>Pack the terminal for shipment by using the following procedure. <A HREF="figure7-2.html">Figure 7-2</A>
shows the terminal's packaging. <A HREF="figure7-3.html">Figure 7-3</A> shows power switch and
cable locations.</P>
<OL>
<LI>Turn the power switch off (0).</LI>
<LI>Disconnect all cables at the back of the terminal.</LI>
<LI>Place the monitor and keyboard in plastic bags.</LI>
<LI>Place the packing material for the left side (facing the front of the
terminal) on a flat surface, with the cutouts facing up. Place the monitor
in the large cutout.</LI>
<LI>Route the keyboard cable behind the keyboard. Place the connector
in the small cutout.</LI>
<LI>Place the keyboard cover over the keys, then place the keyboard
into the small cutout.</LI>
<LI>Place the packing material for the right side over the monitor and
keyboard.</LI>
<LI>Place the packaged terminal and power cable in the shipping carton.
Fold the carton flaps and tape the carton closed with sealing tape.</LI>
</OL>
<H2 ID="S7.5">Installation Procedure</H2>
<P>Install the terminal by using the following procedure. <A HREF="figure7-3.html">Figure 7-3</A> shows
switch and cable locations.</P>
<OL>
<LI>Perform the unpacking and inspection procedure in this chapter.</LI>
<LI>Check the terminal for the correct voltage range selection. The terminal
can operate with either 120 Vac or 220-240 Vac input power.
<P CLASS="note">CAUTION: Failure to select the proper voltage range will damage
the terminal.</P>
<P>A label over the power receptacle indicates the factory-selected input
voltage range. Check this label, the voltage selection switch, and
fuse for the correct voltage range. Make sure the voltage range
matches your local ac power source.</P>
<P>Select 120 volts by performing the following procedure.</P>
<OL>
<LI>Set the voltage selection switch to 115 (operating range 99-128
Vac). On some terminals, the setting is 100 (operating range 87-107 Vac).</LI>
<LI>Remove the fuse holder cap by pressing in and turning counter-clockwise.
Check for a 1.25 A fuse (DIGITAL PN 90-00020-01). Replace
the fuse and fuse holder cap by pressing in and turning
clockwise.</LI>
</OL>
<P>Select 220-240 volts by performing the following procedure.</P>
<OL>
<LI>Set the voltage selection switch to 230 (operating range 198-256
Vac). On some terminals, the setting is 250 (operating range 222-268 Vac).</LI>
<LI>Remove the fuse holder cap by pressing in and turning counter-clockwise.
Check for a 0.75 A slow blow fuse (DIGITAL PN 12-11237-00).
Replace the fuse and fuse holder cap by pressing in
and turning clockwise.</LI>
</OL></LI>
<LI>Remove the backing paper from the self-sticking SET-UP label and
attach to the bottom of the keyboard.</LI>
<LI>If necessary, install the 20 mA current loop option (VT1XX-CA). Perform
the option installation and checkout procedures in <A HREF="chapter8.html">Chapter 8</A>.</LI>
<LI>When using the standard modem connector, selection the internal communication
switches. See <A HREF="#S7.5.1">Communication Switch Selection</A> in this
chapter when selecting the communication switches.
<P CLASS="note">NOTE: When using the 20 mA current loop option, the terminal ignores
the position of the communication switches.</P></LI>
<LI>Place the keyboard in front of the terminal. Plug the keyboard into the
keyboard connector.</LI>
<LI>Connect the communication cable to the terminal. See <A HREF="#S7.5.2">Communication
and Printer Cables</A> in this chapter for more information. Also,
see <A HREF="chapter6.html">Chapter 6</A> for information about connector use and signal/pin
definitions.</LI>
<LI>Connect the printer cable to the printer interface connector. See the
sections referenced in step 7.</LI>
<LI>Connect the external video device, such as a video monitor, to the
video output connector. The terminal uses a 75-ohm BNC connector.
See <A HREF="appendixa.html">Appendix A</A> for detailed specifications for this output.</LI>
<LI>Connect one end of the ac power cord to the terminal and the other
end to a nonswitched, grounded receptacle.
<P CLASS="note">NOTE: Make sure the power switch is off (0) before connecting the
power cord.</P></LI>
<LI>Perform the power-up and checkout procedure in this chapter.</LI>
</OL>
<H3 ID="S7.5.1">Internal Communication Switch Selection</H3>
<P>The terminal has ten internal communication switches to connect or disconnect
modem communication lines. See <A HREF="chapter6.html">Chapter 6</A> for more information
on these communication lines. Select these switches by using the following
procedure.</P>
<OL>
<LI>Turn the power switch off (0) and loosen the two captive screws
holding the access cover in place (<A TITLE="Access Cover Screw Locations" HREF="figure7-4.html">Figure 7-4</A>).</LI>
<LI>Pull the access cover straight out from the back of the terminal, until
loose. Then move the cover to the left, off the supporting studs. Finally,
remove the cover by pulling straight out (<A TITLE="Access Cover Removal" HREF="figure7-5.html">Figure 7-5</A>).</LI>
<LI>Select the communication switches. The terminal uses one communication
switch pack. However, there are three possible types of
switch packs used; two types use rocker switches and one type
uses slide switches.
<P>To select the rocker switch, press the side of the switch that corresponds
to the desired selection. To select the slide switch, push the
switch tab to the side that corresponds to the desired setting. <A TITLE="Internal Communication Switch Locations" HREF="figure7-6.html">Figure
7-6</A> shows the location of the communication switches. <A TITLE="Internal Communication Switch Selections" HREF="figure7-7.html">Figure 7-7</A>
shows the communication lines connected (on, closed) or disconnected
(off, open) by these switches.</P>
<P CLASS="note">NOTE: Always use a small-blade screwdriver or ball-point pen to
change the communication switches. Never use a lead pencil.</P></LI>
<LI>Install the access cover.
<P CLASS="note">CAUTION: You may damage the access cover by tightening the
captive screws too much.</P></LI>
</OL>
<H3 ID="S7.5.2">Communication and Printer Cables</H3>
<P>You can order communication and printer cables from A&amp;SG. See <A HREF="chapter10.html">Chapter
10</A> for part numbers and ordering information. <A TITLE="Interface Cables" HREF="table7-1.html">Table 7-1</A> describes each
communication cable used, and <A TITLE="Cable Connection Examples" HREF="figure7-8.html">Figure 7-8</A> shows connection examples
for each cable.</P>
<H2 ID="S7.6">Power-Up and Checkout Procedure</H2>
<P>A power-up self-test procedure verifies the terminal operation each time
you power up. Power up and check out the terminal by using the following
procedure. See <A HREF="figure7-3.html">Figure 7-3</A>.</P>
<OL>
<LI><P>Turn the power switch on (1). The terminal automatically runs the
power-up self-test. The test provides the following indications.</P>
<UL>
<LI>The terminal displays test data, the wait message, then erases
screen. (The test data and wait message are not visible if the terminal
is not warmed up).</LI>
<LI>All keyboard indicators turn on and off, and either the ON LINE or
OFF LINE stays on. The other indicators may stay on or off, depending
on feature selections and received modem signals.</LI>
<LI>A bell tone sounds.</LI>
<LI>The cursor appears in the upper-left corner of the screen.</LI>
</UL>
<P>When the power-up self-test finds an error, the terminal provides one
of the following indications.</P>
<UL>
<LI>Does not perform the step 1 sequence.</LI>
<LI>Displays character at the cursor position.</LI>
<LI>Sounds several bell tones.</LI>
</UL>
<P>See <A HREF="chapter9.html">Chapter 9</A> for more information about self-test failure.</P></LI>
<LI>Enter SET-UP to verify a successful test. A SET-UP display should
appear on the screen. If not call your local DIGITAL Field Service Office.</LI>
<LI>If the terminal powers up correctly, select the desired SET-UP features
as described in <A HREF="chapter3.html">Chapter 3</A>.</LI>
<LI>After you select the SET-UP features, record the feature selections
on the SET-UP label attached to the keyboard.</LI>
<LI>Save the SET-UP features by using <SPAN CLASS="keyname">SHIFT</SPAN> and <SPAN CLASS="keyname">S</SPAN>. See <A HREF="chapter3.html">Chapter 3</A> for
more information about saving SET-UP features.</LI>
</OL>
<DIV CLASS="navbar"><HR>
<TABLE WIDTH="100%">
<COL SPAN="3" WIDTH="33%">
<TBODY>
<TR>
<TD ALIGN="LEFT"><A HREF="chapter6.html">Chapter 6</A></TD>
<TD ALIGN="CENTER"><A HREF="contents.html">Contents</A></TD>
<TD ALIGN="RIGHT"><A HREF="chapter8.html">Chapter 8</A></TD>
</TR>
</TBODY>
</TABLE>
<DIV CLASS="navbot">http://vt100.net/docs/vt102-ug/chapter7.html</DIV></DIV>
</BODY>
</HTML>