aboutsummaryrefslogtreecommitdiffstats
path: root/target/linux/mediatek/patches-5.15/806-v6.2-thermal-mediatek-add-support-for-MT7986-and-MT7981.patch
blob: 65311d5718d9f9cdebab527a3e23f3027fa8958a (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
From aa957c759b1182aee00cc35178667f849f941b42 Mon Sep 17 00:00:00 2001
From: Daniel Golle <daniel@makrotopia.org>
Date: Wed, 30 Nov 2022 13:19:39 +0000
Subject: [PATCH 2/2] thermal: mediatek: add support for MT7986 and MT7981

Add support for V3 generation thermal found in MT7986 and MT7981 SoCs.
Brings code to assign values from efuse as well as new function to
convert raw temperature to millidegree celsius, as found in MediaTek's
SDK sources (but cleaned up and de-duplicated)

[1]: https://git01.mediatek.com/plugins/gitiles/openwrt/feeds/mtk-openwrt-feeds/+/baf36c7eef477aae1f8f2653b6c29e2caf48475b
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
---
 drivers/thermal/mtk_thermal.c | 137 ++++++++++++++++++++++++++++++++--
 1 file changed, 132 insertions(+), 5 deletions(-)

--- a/drivers/thermal/mtk_thermal.c
+++ b/drivers/thermal/mtk_thermal.c
@@ -150,6 +150,20 @@
 #define CALIB_BUF1_VALID_V2(x)		(((x) >> 4) & 0x1)
 #define CALIB_BUF1_O_SLOPE_SIGN_V2(x)	(((x) >> 3) & 0x1)
 
+/*
+ * Layout of the fuses providing the calibration data
+ * These macros can be used for MT7981 and MT7986.
+ */
+#define CALIB_BUF0_ADC_GE_V3(x)		(((x) >> 0) & 0x3ff)
+#define CALIB_BUF0_DEGC_CALI_V3(x)	(((x) >> 20) & 0x3f)
+#define CALIB_BUF0_O_SLOPE_V3(x)	(((x) >> 26) & 0x3f)
+#define CALIB_BUF1_VTS_TS1_V3(x)	(((x) >> 0) & 0x1ff)
+#define CALIB_BUF1_VTS_TS2_V3(x)	(((x) >> 21) & 0x1ff)
+#define CALIB_BUF1_VTS_TSABB_V3(x)	(((x) >> 9) & 0x1ff)
+#define CALIB_BUF1_VALID_V3(x)		(((x) >> 18) & 0x1)
+#define CALIB_BUF1_O_SLOPE_SIGN_V3(x)	(((x) >> 19) & 0x1)
+#define CALIB_BUF1_ID_V3(x)		(((x) >> 20) & 0x1)
+
 enum {
 	VTS1,
 	VTS2,
@@ -163,6 +177,7 @@ enum {
 enum mtk_thermal_version {
 	MTK_THERMAL_V1 = 1,
 	MTK_THERMAL_V2,
+	MTK_THERMAL_V3,
 };
 
 /* MT2701 thermal sensors */
@@ -245,6 +260,27 @@ enum mtk_thermal_version {
 /* The calibration coefficient of sensor  */
 #define MT8183_CALIBRATION	153
 
+/* AUXADC channel 11 is used for the temperature sensors */
+#define MT7986_TEMP_AUXADC_CHANNEL	11
+
+/* The total number of temperature sensors in the MT7986 */
+#define MT7986_NUM_SENSORS		1
+
+/* The number of banks in the MT7986 */
+#define MT7986_NUM_ZONES		1
+
+/* The number of sensing points per bank */
+#define MT7986_NUM_SENSORS_PER_ZONE	1
+
+/* MT7986 thermal sensors */
+#define MT7986_TS1			0
+
+/* The number of controller in the MT7986 */
+#define MT7986_NUM_CONTROLLER		1
+
+/* The calibration coefficient of sensor  */
+#define MT7986_CALIBRATION		165
+
 struct mtk_thermal;
 
 struct thermal_bank_cfg {
@@ -388,6 +424,14 @@ static const int mt7622_mux_values[MT762
 static const int mt7622_vts_index[MT7622_NUM_SENSORS] = { VTS1 };
 static const int mt7622_tc_offset[MT7622_NUM_CONTROLLER] = { 0x0, };
 
+/* MT7986 thermal sensor data */
+static const int mt7986_bank_data[MT7986_NUM_SENSORS] = { MT7986_TS1, };
+static const int mt7986_msr[MT7986_NUM_SENSORS_PER_ZONE] = { TEMP_MSR0, };
+static const int mt7986_adcpnp[MT7986_NUM_SENSORS_PER_ZONE] = { TEMP_ADCPNP0, };
+static const int mt7986_mux_values[MT7986_NUM_SENSORS] = { 0, };
+static const int mt7986_vts_index[MT7986_NUM_SENSORS] = { VTS1 };
+static const int mt7986_tc_offset[MT7986_NUM_CONTROLLER] = { 0x0, };
+
 /*
  * The MT8173 thermal controller has four banks. Each bank can read up to
  * four temperature sensors simultaneously. The MT8173 has a total of 5
@@ -551,6 +595,30 @@ static const struct mtk_thermal_data mt8
 	.version = MTK_THERMAL_V1,
 };
 
+/*
+ * MT7986 uses AUXADC Channel 11 for raw data access.
+ */
+static const struct mtk_thermal_data mt7986_thermal_data = {
+	.auxadc_channel = MT7986_TEMP_AUXADC_CHANNEL,
+	.num_banks = MT7986_NUM_ZONES,
+	.num_sensors = MT7986_NUM_SENSORS,
+	.vts_index = mt7986_vts_index,
+	.cali_val = MT7986_CALIBRATION,
+	.num_controller = MT7986_NUM_CONTROLLER,
+	.controller_offset = mt7986_tc_offset,
+	.need_switch_bank = true,
+	.bank_data = {
+		{
+			.num_sensors = 1,
+			.sensors = mt7986_bank_data,
+		},
+	},
+	.msr = mt7986_msr,
+	.adcpnp = mt7986_adcpnp,
+	.sensor_mux_values = mt7986_mux_values,
+	.version = MTK_THERMAL_V3,
+};
+
 /**
  * raw_to_mcelsius - convert a raw ADC value to mcelsius
  * @mt:	The thermal controller
@@ -605,6 +673,22 @@ static int raw_to_mcelsius_v2(struct mtk
 	return (format_2 - tmp) * 100;
 }
 
+static int raw_to_mcelsius_v3(struct mtk_thermal *mt, int sensno, s32 raw)
+{
+	s32 tmp;
+
+	if (raw == 0)
+		return 0;
+
+	raw &= 0xfff;
+	tmp = 100000 * 15 / 16 * 10000;
+	tmp /= 4096 - 512 + mt->adc_ge;
+	tmp /= 1490;
+	tmp *= raw - mt->vts[sensno] - 2900;
+
+	return mt->degc_cali * 500 - tmp;
+}
+
 /**
  * mtk_thermal_get_bank - get bank
  * @bank:	The bank
@@ -885,6 +969,25 @@ static int mtk_thermal_extract_efuse_v2(
 	return 0;
 }
 
+static int mtk_thermal_extract_efuse_v3(struct mtk_thermal *mt, u32 *buf)
+{
+	if (!CALIB_BUF1_VALID_V3(buf[1]))
+		return -EINVAL;
+
+	mt->adc_ge = CALIB_BUF0_ADC_GE_V3(buf[0]);
+	mt->degc_cali = CALIB_BUF0_DEGC_CALI_V3(buf[0]);
+	mt->o_slope = CALIB_BUF0_O_SLOPE_V3(buf[0]);
+	mt->vts[VTS1] = CALIB_BUF1_VTS_TS1_V3(buf[1]);
+	mt->vts[VTS2] = CALIB_BUF1_VTS_TS2_V3(buf[1]);
+	mt->vts[VTSABB] = CALIB_BUF1_VTS_TSABB_V3(buf[1]);
+	mt->o_slope_sign = CALIB_BUF1_O_SLOPE_SIGN_V3(buf[1]);
+
+	if (CALIB_BUF1_ID_V3(buf[1]) == 0)
+		mt->o_slope = 0;
+
+	return 0;
+}
+
 static int mtk_thermal_get_calibration_data(struct device *dev,
 					    struct mtk_thermal *mt)
 {
@@ -895,6 +998,7 @@ static int mtk_thermal_get_calibration_d
 
 	/* Start with default values */
 	mt->adc_ge = 512;
+	mt->adc_oe = 512;
 	for (i = 0; i < mt->conf->num_sensors; i++)
 		mt->vts[i] = 260;
 	mt->degc_cali = 40;
@@ -920,10 +1024,20 @@ static int mtk_thermal_get_calibration_d
 		goto out;
 	}
 
-	if (mt->conf->version == MTK_THERMAL_V1)
+	switch (mt->conf->version) {
+	case MTK_THERMAL_V1:
 		ret = mtk_thermal_extract_efuse_v1(mt, buf);
-	else
+		break;
+	case MTK_THERMAL_V2:
 		ret = mtk_thermal_extract_efuse_v2(mt, buf);
+		break;
+	case MTK_THERMAL_V3:
+		ret = mtk_thermal_extract_efuse_v3(mt, buf);
+		break;
+	default:
+		ret = -EINVAL;
+		break;
+	}
 
 	if (ret) {
 		dev_info(dev, "Device not calibrated, using default calibration values\n");
@@ -954,6 +1068,10 @@ static const struct of_device_id mtk_the
 		.data = (void *)&mt7622_thermal_data,
 	},
 	{
+		.compatible = "mediatek,mt7986-thermal",
+		.data = (void *)&mt7986_thermal_data,
+	},
+	{
 		.compatible = "mediatek,mt8183-thermal",
 		.data = (void *)&mt8183_thermal_data,
 	}, {
@@ -1068,15 +1186,24 @@ static int mtk_thermal_probe(struct plat
 		goto err_disable_clk_auxadc;
 	}
 
-	if (mt->conf->version == MTK_THERMAL_V2) {
+	if (mt->conf->version != MTK_THERMAL_V1) {
 		mtk_thermal_turn_on_buffer(apmixed_base);
 		mtk_thermal_release_periodic_ts(mt, auxadc_base);
 	}
 
-	if (mt->conf->version == MTK_THERMAL_V1)
+	switch (mt->conf->version) {
+	case MTK_THERMAL_V1:
 		mt->raw_to_mcelsius = raw_to_mcelsius_v1;
-	else
+		break;
+	case MTK_THERMAL_V2:
 		mt->raw_to_mcelsius = raw_to_mcelsius_v2;
+		break;
+	case MTK_THERMAL_V3:
+		mt->raw_to_mcelsius = raw_to_mcelsius_v3;
+		break;
+	default:
+		break;
+	}
 
 	for (ctrl_id = 0; ctrl_id < mt->conf->num_controller ; ctrl_id++)