diff --git a/target/linux/ramips/patches-5.4/0123-mips-ralink-manage-low-reset-lines.patch b/target/linux/ramips/patches-5.4/0123-mips-ralink-manage-low-reset-lines.patch
deleted file mode 100644
index bdf98f223c..0000000000
--- a/target/linux/ramips/patches-5.4/0123-mips-ralink-manage-low-reset-lines.patch
+++ /dev/null
@@ -1,45 +0,0 @@
-From 3f9ef7785a9cd69cb75f5e2ea4ca79a24752e496 Mon Sep 17 00:00:00 2001
-From: Sander Vanheule <sander@svanheule.net>
-Date: Wed, 3 Feb 2021 10:21:41 +0100
-Subject: MIPS: ralink: manage low reset lines
-
-Reset lines with indices smaller than 8 are currently considered invalid
-by the rt2880-reset reset controller.
-
-The MT7621 SoC uses a number of these low reset lines. The DTS defines
-reset lines "hsdma", "fe", and "mcm" with respective values 5, 6, and 2.
-As a result of the above restriction, these resets cannot be asserted or
-de-asserted by the reset controller. In cases where the bootloader does
-not de-assert these lines, this results in e.g. the MT7621's internal
-switch staying in reset.
-
-Change the reset controller to only ignore the system reset, so all
-reset lines with index greater than 0 are considered valid.
-
-Signed-off-by: Sander Vanheule <sander@svanheule.net>
-Acked-by: John Crispin <john@phrozen.org>
-Signed-off-by: Thomas Bogendoerfer <tsbogend@alpha.franken.de>
----
- arch/mips/ralink/reset.c | 4 ++--
- 1 file changed, 2 insertions(+), 2 deletions(-)
-
---- a/arch/mips/ralink/reset.c
-+++ b/arch/mips/ralink/reset.c
-@@ -27,7 +27,7 @@ static int ralink_assert_device(struct r
- {
- u32 val;
-
-- if (id < 8)
-+ if (id == 0)
- return -1;
-
- val = rt_sysc_r32(SYSC_REG_RESET_CTRL);
-@@ -42,7 +42,7 @@ static int ralink_deassert_device(struct
- {
- u32 val;
-
-- if (id < 8)
-+ if (id == 0)
- return -1;
-
- val = rt_sysc_r32(SYSC_REG_RESET_CTRL);