From 09dae4feac941f3a6190cf361479bf8b2ba194bf Mon Sep 17 00:00:00 2001 From: Christian Lamparter Date: Tue, 19 Jul 2022 19:46:38 +0200 Subject: ipq806x: Archer VR2600: fix switch ports numbering The order of LAN ports shown in Luci is reversed compared to what is written on the case of the device. Fix the order so that they match. Fixes: #10275 Signed-off-by: Christian Lamparter (cherry picked from commit 69ea671320c936e72f554348475eeebcab383b42) --- target/linux/ipq806x/base-files/etc/board.d/02_network | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) (limited to 'target') diff --git a/target/linux/ipq806x/base-files/etc/board.d/02_network b/target/linux/ipq806x/base-files/etc/board.d/02_network index 1e00b97092..d6c2c0e5c2 100755 --- a/target/linux/ipq806x/base-files/etc/board.d/02_network +++ b/target/linux/ipq806x/base-files/etc/board.d/02_network @@ -22,8 +22,7 @@ compex,wpq864 |\ netgear,d7800 |\ netgear,r7500 |\ netgear,r7500v2 |\ -qcom,ipq8064-ap148 |\ -tplink,vr2600v) +qcom,ipq8064-ap148) ucidef_add_switch "switch0" \ "1:lan" "2:lan" "3:lan" "4:lan" "6@eth1" "5:wan" "0@eth0" ;; @@ -51,7 +50,8 @@ nec,wg2600hp3) "2:lan" "3:lan" "4:lan" "5:lan" "0@eth1" "1:wan" "6@eth0" ;; netgear,r7800 |\ -tplink,c2600) +tplink,c2600 |\ +tplink,vr2600v) ucidef_add_switch "switch0" \ "1:lan:4" "2:lan:3" "3:lan:2" "4:lan:1" "6@eth1" "5:wan" "0@eth0" ;; -- cgit v1.2.3