aboutsummaryrefslogtreecommitdiffstats
path: root/tools
diff options
context:
space:
mode:
authorHenryk Heisig <hyniu@o2.pl>2018-01-15 06:44:14 +0100
committerPiotr Dymacz <pepe2k@gmail.com>2018-04-07 00:09:05 +0200
commitc0742307a18178ee7d2cee1fc6b0e199ccb1e1fa (patch)
treed760d522791c179b1dc200adf2656b92b36f9417 /tools
parentb834487203996e71c5ea25f83488873483b96522 (diff)
downloadupstream-c0742307a18178ee7d2cee1fc6b0e199ccb1e1fa.tar.gz
upstream-c0742307a18178ee7d2cee1fc6b0e199ccb1e1fa.tar.bz2
upstream-c0742307a18178ee7d2cee1fc6b0e199ccb1e1fa.zip
ar71xx: add support for TP-Link Archer C60 v2
TP-Link Archer C60 v2 is a dual-band AC1350 router, based on Qualcomm/Atheros QCA9561 + QCA9886. Specification: - 775/650/258 MHz (CPU/DDR/AHB) - 64 MB of RAM (DDR2) - 8 MB of FLASH (SPI NOR) - 3T3R 2.4 GHz - 2T2R 5 GHz - 5x 10/100 Mbps Ethernet - 7x LED, 2x button - UART header on PCB Flash instruction (web): Download lede-ar71xx-generic-archer-c60-v2-squashfs-factory.bin and use OEM System Tools - Firmware Upgrade site. Flash instruction (recovery): 1. Set PC to fixed IP address 192.168.0.66 2. Download lede-ar71xx-generic-archer-c60-v2-squashfs-factory.bin and rename it to tp_recovery.bin 3. Start a tftp server with the file tp_recovery.bin in its root directory 4. Turn off the router 5. Press and hold reset button 6. Turn on router with the reset button pressed and wait ~15 seconds 7. Release the reset button and after a short time the firmware should be transferred from the tftp server 8. Wait ~30 second to complete recovery Flash instruction (under U-Boot, using UART): tftp 0x81000000 lede-ar71xx-...-sysupgrade.bin erase 0x9f030000 +$filesize cp.b $fileaddr 0x9f030000 $filesize reset Signed-off-by: Henryk Heisig <hyniu@o2.pl>
Diffstat (limited to 'tools')
-rw-r--r--tools/firmware-utils/src/tplink-safeloader.c38
1 files changed, 38 insertions, 0 deletions
diff --git a/tools/firmware-utils/src/tplink-safeloader.c b/tools/firmware-utils/src/tplink-safeloader.c
index eb99241136..2e83b71c44 100644
--- a/tools/firmware-utils/src/tplink-safeloader.c
+++ b/tools/firmware-utils/src/tplink-safeloader.c
@@ -451,6 +451,43 @@ static struct device_info boards[] = {
.last_sysupgrade_partition = "file-system",
},
+ /** Firmware layout for the C60v2 */
+ {
+ .id = "ARCHER-C60-V2",
+ .vendor = "",
+ .support_list =
+ "SupportList:\r\n"
+ "{product_name:Archer C60,product_ver:2.0.0,special_id:42520000}\r\n"
+ "{product_name:Archer C60,product_ver:2.0.0,special_id:45550000}\r\n"
+ "{product_name:Archer C60,product_ver:2.0.0,special_id:55530000}\r\n",
+ .support_trail = '\x00',
+ .soft_ver = "soft_ver:2.0.0\n",
+
+ .partitions = {
+ {"factory-boot", 0x00000, 0x1fb00},
+ {"default-mac", 0x1fb00, 0x00200},
+ {"pin", 0x1fd00, 0x00100},
+ {"product-info", 0x1fe00, 0x00100},
+ {"device-id", 0x1ff00, 0x00100},
+ {"fs-uboot", 0x20000, 0x10000},
+ {"os-image", 0x30000, 0x180000},
+ {"file-system", 0x1b0000, 0x620000},
+ {"soft-version", 0x7d9500, 0x00100},
+ {"support-list", 0x7d9600, 0x00100},
+ {"extra-para", 0x7d9700, 0x00100},
+ {"profile", 0x7d9800, 0x03000},
+ {"default-config", 0x7dc800, 0x03000},
+ {"partition-table", 0x7df800, 0x00800},
+ {"user-config", 0x7e0000, 0x0c000},
+ {"certificate", 0x7ec000, 0x04000},
+ {"radio", 0x7f0000, 0x10000},
+ {NULL, 0, 0}
+ },
+
+ .first_sysupgrade_partition = "os-image",
+ .last_sysupgrade_partition = "file-system",
+ },
+
/** Firmware layout for the C5 */
{
.id = "ARCHER-C5-V2",
@@ -1343,6 +1380,7 @@ static void build_image(const char *output,
/* Some devices need the extra-para partition to accept the firmware */
if (strcasecmp(info->id, "ARCHER-C25-V1") == 0 ||
+ strcasecmp(info->id, "ARCHER-C60-V2") == 0 ||
strcasecmp(info->id, "TLWR1043NV5") == 0) {
const char mdat[11] = {0x00, 0x00, 0x00, 0x02, 0x00, 0x00, 0x00, 0x00, 0x01, 0x00, 0x00};
parts[5] = put_data("extra-para", mdat, 11);