lantiq: unify Fritz!Box LED mappings
This commit unifies the LED mapping of the AVM Fritz!Box routers, which
have a combined Power/DSL LED.
With the stock firmware, the Power LED has the following
characteristics:
- Blink when DSL sync is being established
- Solid when DSL sync is present
We can't completely resemble this behavior in OpenWrt. Currently, the
Power LED is completely off, when DSL sync is missing. This is not
really helpful, as a user might have the impression, that he bricked his
device.
Instead, map the Info-LED to the state of the DSL connection.
There is no consistent behavior for the Info-LED in the stock
firmware, as the user can set it's function by himself. The DSL
connection state is one possible option for the Info LED there.
Also use the red Power LED to indicate a running upgrade, in case the
board has a two-color Power LED.
Signed-off-by: David Bauer <mail@david-bauer.net>
(cherry picked from commit 3032bf7f89e8ad5b69ab2f031287f475e5d2b829)
Diffstat (limited to 'target')
4 files changed, 5 insertions, 6 deletions
diff --git a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ3370-REV2.dtsi b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ3370-REV2.dtsi index 9a0359d1cc..e86e544945 100644 --- a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ3370-REV2.dtsi +++ b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ3370-REV2.dtsi @@ -15,7 +15,7 @@ led-boot = &power_green; led-failsafe = &power_red; led-running = &power_green; - led-upgrade = &power_green; + led-upgrade = &power_red; led-dsl = &dsl; led-internet = &info_green; diff --git a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7312.dts b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7312.dts index 796b941ede..29da0fb8e5 100644 --- a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7312.dts +++ b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7312.dts @@ -18,8 +18,7 @@ led-running = &power; led-upgrade = &power; - led-internet = &info_green; - led-dsl = &power; + led-dsl = &info_green; led-wifi = &wlan; }; diff --git a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7320.dts b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7320.dts index a4afca11fa..89fc3858b7 100644 --- a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7320.dts +++ b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ7320.dts @@ -18,8 +18,7 @@ led-running = &power; led-upgrade = &power; - led-internet = &info_green; - led-dsl = &power; + led-dsl = &info_green; led-wifi = &wlan; }; diff --git a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ736X.dtsi b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ736X.dtsi index 9c1d2db8fa..8ed23deb44 100644 --- a/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ736X.dtsi +++ b/target/linux/lantiq/files-4.14/arch/mips/boot/dts/FRITZ736X.dtsi @@ -17,7 +17,8 @@ led-boot = &power_green; led-failsafe = &power_red; led-running = &power_green; - led-upgrade = &power_green; + led-upgrade = &power_red; + led-dsl = &info_green; led-wifi = &wifi; }; |