aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorOlaf Hering <olaf@aepfle.de>2012-11-13 18:00:57 +0000
committerOlaf Hering <olaf@aepfle.de>2012-11-13 18:00:57 +0000
commitca8ae5103f176bee871d9ab1557cb9b8586b9ec7 (patch)
treef25fbdbf32a6b0d76785d050a19bcdddd1acb34e
parent7da2ea18d92452de391faf4232b01a62ac8fc3d9 (diff)
downloadxen-ca8ae5103f176bee871d9ab1557cb9b8586b9ec7.tar.gz
xen-ca8ae5103f176bee871d9ab1557cb9b8586b9ec7.tar.bz2
xen-ca8ae5103f176bee871d9ab1557cb9b8586b9ec7.zip
xend/pvscsi: update sysfs parser for Linux 3.0
The sysfs parser for /sys/bus/scsi/devices understands only the layout of kernel version 2.6.16. This looks as follows: /sys/bus/scsi/devices/1:0:0:0/block:sda is a symlink to /sys/block/sda/ /sys/bus/scsi/devices/1:0:0:0/scsi_generic:sg1 is a symlink to /sys/class/scsi_generic/sg1 Both directories contain a 'dev' file with the major:minor information. This patch updates the used regex strings to match also the colon to make it more robust against possible future changes. In kernel version 3.0 the layout changed: /sys/bus/scsi/devices/ contains now additional symlinks to directories such as host1 and target1:0:0. This patch ignores these as they do not point to the desired scsi devices. They just clutter the devices array. The directory layout in '1:0:0:0' changed as well, the 'type:name' notation was replaced with 'type/name' directories: /sys/bus/scsi/devices/1:0:0:0/block/sda/ /sys/bus/scsi/devices/1:0:0:0/scsi_generic/sg1/ Both directories contain a 'dev' file with the major:minor information. This patch adds additional code to walk the subdir to find the 'dev' file to make sure the given subdirectory is really the kernel name. In addition this patch makes sure devname is not None. Signed-off-by: Olaf Hering <olaf@aepfle.de> Acked-by: Ian Campbell <ian.campbell@citrix.com> Committed-by: Ian Campbell <ian.campbell@citrix.com> xen-unstable changeset: 26010:cff10030c6ea Backport-requested-by: Olaf Hering <olaf@aepfle.de> Committed-by: Ian Jackson <ian.jackson@eu.citrix.com>
-rw-r--r--tools/python/xen/util/vscsi_util.py28
1 files changed, 22 insertions, 6 deletions
diff --git a/tools/python/xen/util/vscsi_util.py b/tools/python/xen/util/vscsi_util.py
index 38cdff4f2b..5872e65916 100644
--- a/tools/python/xen/util/vscsi_util.py
+++ b/tools/python/xen/util/vscsi_util.py
@@ -130,20 +130,36 @@ def _vscsi_get_scsidevices_by_sysfs():
for dirpath, dirnames, files in os.walk(sysfs_mnt + SYSFS_SCSI_PATH):
for hctl in dirnames:
+ if len(hctl.split(':')) != 4:
+ continue
paths = os.path.join(dirpath, hctl)
devname = None
sg = None
scsi_id = None
for f in os.listdir(paths):
realpath = os.path.realpath(os.path.join(paths, f))
- if re.match('^block', f) or \
- re.match('^tape', f) or \
- re.match('^scsi_changer', f) or \
- re.match('^onstream_tape', f):
+ if re.match('^block:', f) or \
+ re.match('^tape:', f) or \
+ re.match('^scsi_changer:', f) or \
+ re.match('^onstream_tape:', f):
devname = os.path.basename(realpath)
-
- if re.match('^scsi_generic', f):
+ elif f == "block" or \
+ f == "tape" or \
+ f == "scsi_changer" or \
+ f == "onstream_tape":
+ for dir in os.listdir(os.path.join(paths, f)):
+ if os.path.exists(os.path.join(paths, f, dir, "dev")):
+ devname = os.path.basename(dir)
+
+ if re.match('^scsi_generic:', f):
sg = os.path.basename(realpath)
+ elif f == "scsi_generic":
+ for dir in os.listdir(os.path.join(paths, f)):
+ if os.path.exists(os.path.join(paths, f, dir, "dev")):
+ sg = os.path.basename(dir)
+ if sg:
+ if devname is None:
+ devname = sg
scsi_id = _vscsi_get_scsiid(sg)
devices.append([hctl, devname, sg, scsi_id])