49
|
From: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Date: Fri, 23 Oct 2015 18:01:04 +0530
Subject: [PATCH] ath10k: remove send completion validation in diag
read/write
CE diag window access is serialized (it has to be by design) so
there's no way to get a different send completion. so there's no
need for post completion validation.
Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
---
--- a/drivers/net/wireless/ath/ath10k/pci.c
+++ b/drivers/net/wireless/ath/ath10k/pci.c
@@ -920,16 +920,6 @@ static int ath10k_pci_diag_read_mem(stru
}
}
- if (nbytes != completed_nbytes) {
- ret = -EIO;
- goto done;
- }
-
- if (buf != (u32)address) {
- ret = -EIO;
- goto done;
- }
-
i = 0;
while (ath10k_ce_completed_recv_next_nolock(ce_diag, NULL, &buf,
&completed_nbytes,
@@ -1094,16 +1084,6 @@ static int ath10k_pci_diag_write_mem(str
}
}
- if (nbytes != completed_nbytes) {
- ret = -EIO;
- goto done;
- }
-
- if (buf != ce_data) {
- ret = -EIO;
- goto done;
- }
-
i = 0;
while (ath10k_ce_completed_recv_next_nolock(ce_diag, NULL, &buf,
&completed_nbytes,
|