authorMathias Kresin <dev@kresin.me>2016-06-19 16:33:44 +0200
committerJohn Crispin <john@phrozen.org>2016-06-20 11:45:44 +0200
commit551c9c830027b7749895e3ba6b37004570b89e74 (patch)
tree188852cfe6d07ac38fa7846d9aa7612a1006c8f9 /target/linux
parent32012decc327486bdf6564e6cf55a4acfc744efe (diff)
downloadupstream-551c9c830027b7749895e3ba6b37004570b89e74.tar.gz
upstream-551c9c830027b7749895e3ba6b37004570b89e74.tar.bz2
upstream-551c9c830027b7749895e3ba6b37004570b89e74.zip
lantiq: diag - switch off the power led on failsafe
This patch is a follow up to commit 4cf3fd4 "add support for indicating the boot state using three leds". At the time of writing the patch, I wasn't aware that it's possible to switch info failsafe after boot (factory reset). Enabling the failsafe led without disabling the running led causes an unexpected led colour on devices using a single multicolour led to indicate the boot state. Signed-off-by: Mathias Kresin <dev@kresin.me>
Diffstat (limited to 'target/linux')
-rw-r--r--target/linux/lantiq/base-files/etc/diag.sh4
1 files changed, 4 insertions, 0 deletions
diff --git a/target/linux/lantiq/base-files/etc/diag.sh b/target/linux/lantiq/base-files/etc/diag.sh
index 71d6f3e511..f6363b34ac 100644
--- a/target/linux/lantiq/base-files/etc/diag.sh
+++ b/target/linux/lantiq/base-files/etc/diag.sh
@@ -17,6 +17,10 @@ set_state() {
;;
failsafe)
status_led_off
+ [ -n "$running" ] && {
+ status_led="$running"
+ status_led_off
+ }
status_led="$failsafe"
status_led_blink_failsafe
;;