From 4c3e2dc08a11fb1273ca62467f1d06e59866bad3 Mon Sep 17 00:00:00 2001 From: Russell King Date: Tue, 12 Jul 2016 00:04:13 +0100 Subject: [PATCH 729/744] net: mvneta: enable flow control for fixed connections Allow symetric flow control to be enabled for fixed link connections as well as other types of connections by setting the supported and advertised capability bits. Signed-off-by: Russell King --- drivers/net/ethernet/marvell/mvneta.c | 11 +++++++---- 1 file changed, 7 insertions(+), 4 deletions(-) --- a/drivers/net/ethernet/marvell/mvneta.c +++ b/drivers/net/ethernet/marvell/mvneta.c @@ -3114,9 +3114,9 @@ static int mvneta_mac_support(struct net switch (mode) { case MLO_AN_8023Z: state->supported = SUPPORTED_1000baseT_Full | - SUPPORTED_Autoneg | SUPPORTED_Pause; + SUPPORTED_Autoneg; state->advertising = ADVERTISED_1000baseT_Full | - ADVERTISED_Autoneg | ADVERTISED_Pause; + ADVERTISED_Autoneg; state->an_enabled = 1; break; @@ -3127,18 +3127,21 @@ static int mvneta_mac_support(struct net state->supported = PHY_10BT_FEATURES | PHY_100BT_FEATURES | SUPPORTED_1000baseT_Full | - SUPPORTED_Pause | SUPPORTED_Autoneg; state->advertising = ADVERTISED_10baseT_Half | ADVERTISED_10baseT_Full | ADVERTISED_100baseT_Half | ADVERTISED_100baseT_Full | ADVERTISED_1000baseT_Full | - ADVERTISED_Pause | ADVERTISED_Autoneg; state->an_enabled = 1; break; } + + /* All modes support flow control */ + state->supported |= SUPPORTED_Pause; + state->advertising |= ADVERTISED_Pause; + return 0; }