From 849369d6c66d3054688672f97d31fceb8e8230fb Mon Sep 17 00:00:00 2001 From: root Date: Fri, 25 Dec 2015 04:40:36 +0000 Subject: initial_commit --- Documentation/hwmon/ds620 | 34 ++++++++++++++++++++++++++++++++++ 1 file changed, 34 insertions(+) create mode 100644 Documentation/hwmon/ds620 (limited to 'Documentation/hwmon/ds620') diff --git a/Documentation/hwmon/ds620 b/Documentation/hwmon/ds620 new file mode 100644 index 00000000..1fbe3cd9 --- /dev/null +++ b/Documentation/hwmon/ds620 @@ -0,0 +1,34 @@ +Kernel driver ds620 +=================== + +Supported chips: + * Dallas Semiconductor DS620 + Prefix: 'ds620' + Datasheet: Publicly available at the Dallas Semiconductor website + http://www.dalsemi.com/ + +Authors: + Roland Stigge + based on ds1621.c by + Christian W. Zuckschwerdt + +Description +----------- + +The DS620 is a (one instance) digital thermometer and thermostat. It has both +high and low temperature limits which can be user defined (i.e. programmed +into non-volatile on-chip registers). Temperature range is -55 degree Celsius +to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value +returned via sysfs displays post decimal positions. + +The thermostat function works as follows: When configured via platform_data +(struct ds620_platform_data) .pomode == 0 (default), the thermostat output pin +PO is always low. If .pomode == 1, the thermostat is in PO_LOW mode. I.e., the +output pin PO becomes active when the temperature falls below temp1_min and +stays active until the temperature goes above temp1_max. + +Likewise, with .pomode == 2, the thermostat is in PO_HIGH mode. I.e., the PO +output pin becomes active when the temperature goes above temp1_max and stays +active until the temperature falls below temp1_min. + +The PO output pin of the DS620 operates active-low. -- cgit v1.2.3